Monday 13 June 2011

TS-180S Repair Part 3 : Recovery in progress, but the Body Count is Increasing ...

I am aware that it has been a while since my last update on this subject, but work has been progressing quietly in the background as my limited free time has allowed. At least once careful consideration was given to this old lady "becoming a projectile", or to be more serious whether a time was approaching when I would could my losses and put it to one side as it seemed to be taking over my life! However after a brief break I rolled up my sleeves and carried on ...

I am pleased to report that this transceiver now works as a receiver, albeit not on all bands yet, and the frequency display isn't functioning. The time is fast approaching when I will check out the transmitting capability and performance of this venerable transceiver.


The replacement of the dead 2SC1907 in the Q14 position (PLL WBA) allowed me to move on to the next fault (there always seems to be a "next fault" with this radio!) - it still appeared that the PLL circuitry was the problem area.

I revisited the Premix Unit, and although all the various signals appeared to be there I was not convinced that the RF levels were all that they should be.   The Service Manual is rather vague on expected RF levels, though it is very good at expected DC levels around key parts of the circuitry.

Meanwhile, back at the PLL Unit I discovered that the amplified VCO outputs which are fed to the Premix Unit were suspiciously low whereas the VCO output levels themselves seemed to be reasonable.

TS-180S - PLL Circuit (Part)
Attention was therefore drawn to the output stage of this part of the circuit (see excerpt from the circuit), and probing around with my DVM revealed that Q2 (another 2SC1907) had just over a volt between its base and emitter and that Q3, the "unlock output mute" transistor had no volts on its collector.  The other voltages were not very close to those suggested by the Service Manual.

Small signal transistors with a volt showing across base and emitter simply aren't transistors any more (it's a kind of Law of Physics!) and clearly the load choke of the mute transistor was open circuit.

The transistor and choke were replaced, and the radio burst into life! Furthermore, replacing the components restored the DC voltages to being very close to those suggested by the Service Manual, an interesting lesson there for future use. (Note to self:- check the DC voltages first!)

It is interesting to ponder that both of the u/s transistors found so far in this circuit were identical types.  This possibly suggest a quality issue with the manufacturing as I strongly suspect they would have been made at the same time, more than likely from the same piece of material.   Worryingly there are a few more 2SC1907s in this radio!

 Now I have a radio which appears to work as a receiver on most but not all bands - there appear to be some alignment issues still with the PLL, but the frequency display now just shows the "base" frequency for each band, in short the counter isn't working.

I spent a little bit of time investigating the counter issue, and again I am not convinced the signal levels are quite sufficient.  The counted signal is a 40-40.5 MHz VFO-locked signal from the Premix Unit and has to be amplified to a sufficient level to interface with TTL (yes, TTL!) chips, and I don't think this is quite happening, but when I lifted the circuit board to investigate the underside I had a bit of a shock!

TS-180S - counter underside

The components underneath were a surprise, and suggest that the layout of this board isn't what you would call "Kenwood's Finest Moment"!.  However to be fair the added bits are shown in the Service Manual layouts, if you look carefully, and are, in the main added decoupling components to the TTL chip supply pins, or the tying down of unused pins.

Re-sweating some suspicious-looking joints and plated-through holes didn't appear to make any difference, but it's early days yet ...

1 comment:

  1. hi, I have a problem on a kenwood ts 180 s. While I was receiving on wwy (10 mhz) the reception suddenly decreased and disappeared until it disappeared and after that dots appeared on the display and did not receive and transmit. In particular the bands 7.14 and 21 do not give any sign of life and on the display there are only dots, instead on wwy, 1.5, 3.5, 28 and 29 mhz the radio works for the whole band or in part in the sense turning the tuning knob at a certain point stops working and exits on the display. it could help me to solve this problem. my mail is satel457@libero.it. thank you. regards

    ReplyDelete